Journal of Orthopaedics Trauma Surgery and Related Research

Journal of Orthopaedics Trauma Surgery and Related Research

An Official Journal of Polish Society of Orthopaedics and Traumatology

ISSN:1897-2276
e-ISSN: 2449-9145

All submissions of the EM system will be redirected to Online Manuscript Submission System. Authors are requested to submit articles directly to Online Manuscript Submission System of respective journal.

Variations in tibial tray locking mechanisms influence backside wear rates of polyethylene inserts in total knee arthroplasty: A systematic review

Joint Event on 13th International Conference on ARTHRITIS AND RHEUMATOLOGY & 3rd International Conference on ANATOMY AND PHYSIOLOGY

December 9-10, 2019 | Barcelona, Spain

Safa Fassihi

George Washington University, USA

Posters & Accepted Abstracts: J Orthop Trauma Surg Rel Res

Abstract :

Introduction: Modern total knee arthroplasty (TKA) systems use a variety of locking mechanisms to secure the polyethylene insert to the tibial tray. The most common locking mechanisms include peripheral rim locking and dovetail or tongue-in-groove locking mechanisms. Peripheral rim models have a circumferential raised locking mechanism around the tibial tray, whereas dovetail models have grooves in the tibial tray with corresponding areas in the polyethylene insert. The purpose of this review is to provide an update on the evidence regarding the effect of tibial tray locking mechanisms on backside polyethylene wear.

Methods: A Pubmed/MEDLINE query was performed utilizing keywords pertinent to backside wear rates of tibial tray locking mechanisms in TKA. Twelve articles met inclusion criteria and were used in this review.

Results: Backside wear on crosslinked, ultra-high molecular weight polyethylene inserts was most commonly assessed by scanning electron microscopy and the Hood score. These were used on retrieved polyethylene inserts or on a force-displacementcontrolled knee simulator in one study. Data showed that peripheral fit locking mechanisms had slightly decreased backside wear rates when compared to dovetail locking mechanisms. However, one study found that peripheral rim locking with nonpolished trays had the highest amount of backside wear of the locking mechanisms studied. Dovetail mechanism implants showed more abrasive wear than other types. Nonpolished tibial trays had more backside wear than polished trays across all locking mechanism types. These results were found to be similar in both posterior stabilized and cruciate retaining designs.

Conclusions: Peripheral rim locking mechanisms show a slight decrease in the amount of backside wear compared with dovetail locking mechanisms. Additionally, polished trays show a decreased amount of backside wear when compared to nonpolished.

Biography :

Safa Fassihi is a US-based physician pursuing a career in orthopedic total joint arthroplasty. His research focuses on newer arthroplasty techniques and how they affect patient outcomes. In this specific analysis, he collaborated with a US board-certified orthopedic surgeon who performs a high volume of both simultaneous and staged bilateral total knee arthroplasty.

E-mail: scf5071@gmail.com

Select your language of interest to view the total content in your interested language

20+ Million Readerbase
Indexed in

Embase/EXPERTA MEDICA Road Directory of Open Access
Scholarly Resources
Publons MIAR GBL Ministry of Science and Higher
Education
Index Copernicus
Google Scholar citation report
Citations : 281

Journal of Orthopaedics Trauma Surgery and Related Research received 281 citations as per Google Scholar report

Journal of Orthopaedics Trauma Surgery and Related Research peer review process verified at publons
SCImago Journal & Country Rank
Annals of Medical and Health Sciences Research Journal of Orthopaedics Trauma Surgery and Related Research a publication of Polish Society, is a peer-reviewed online journal with quaterly print on demand compilation of issues published.
Submit your Manuscript